yeah that's on the more catastrophic end of scale, nothing can be done at that residential address
why is the US grid so feeble that leakages of this size (and surely a whole neighborhood's gas network getting heated to these temperatures is detectable, right?) aren't automatically disabled by the power company's computers or some other controllers in the network?
They would have to have a lot of switches and network wires connecting them and systems to monitor them. Even then, I doubt this draw would be enough to signal to them that it's a problem. Probably not drawing more than a stove on the cleaning cycle, far below a level that would say, "This area is drawing too much power".
The post say s it was 175A which is substantial but still not enough to notice at a neighborhood level of they were monitoring there.
I see, so less many US house's capacities in total current leakage? This post makes me so grateful I don't have a gas connection in my building
edit: was that total current leaked in the whole neighborhood or just the one house?
From the post it implies that 175A was going into the house (but bypassing the meter so it couldn't be caught there)
So yeah it would be like ~+1 maxed out house running like 10 space heaters
you don't need a lot of computers there, it all can even work without communication with power company. on medium voltage (15kV) lines, that would be reclosers every few kilometers, and these do trip when short to ground (>0.5A) is detected. but no one does that on low voltage, because potential for damage is much less. the difference between euro and american grids is that americans have medium voltage line going down every single street, and because of low voltages and high power draw conductors would have to be of monstrous size otherwise. i understand that GFCIs are rather uncommon out there, and these aren't usually installed in substations either. there are also lots of smaller transformers in american grid and that would make costs of putting all that protection circuitry even higher (in my home village there was 1 15/0.4kV substation per some 250 people, or 80ish houses. americans can have one transformer per one house) gas line could be plastic, so it would be isolating and so it'd be limited to that one house